Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Eur Spine J ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38635086

RESUMO

BACKGROUND CONTEXT: Studies have shown biomechanical superiority of cervical pedicle screw placement over other techniques. However, accurate placement is challenging due to the inherent risk of neurovascular complications. Navigation technology based on intraoperative 3D imaging allows highly accurate screw placement, yet studies specifically investigating screw placement in patients with traumatic atlantoaxial injuries are scarce. The aim of this study was to compare atlantoaxial screw placement as treatment of traumatic instabilities using iCT-based navigation or fluoroscopic-guidance with intraoperative 3D control scans. METHODS: This was a retrospective review of patients with traumatic atlantoaxial injuries treated operatively with dorsal stabilization of C1 and C2. Patients were either assigned to the intraoperative navigation or fluoroscopic-guidance group. Screw accuracy, procedure time, and revisions were compared. RESULTS: Seventy-eight patients were included in this study with 51 patients in the navigation group and 27 patients in the fluoroscopic-guidance group. In total, 312 screws were placed in C1 and C2. Screw accuracy was high in both groups; however, pedicle perforations > 1 mm occurred significantly more often in the fluoroscopic-guidance group (P = 0.02). Procedure time was on average 23 min shorter in the navigation group (P = 0.02). CONCLUSIONS: This study contributes to the available data showing that navigated atlantoaxial screw placement proves to be feasible as well as highly accurate compared to the fluoroscopic-guidance technique without prolonging the time needed for surgery. When comparing these data with other studies, the application of different classification systems for assessment of screw accuracy should be considered.

2.
Int J Emerg Med ; 17(1): 34, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438968

RESUMO

BACKGROUND: Type C pelvic fractures (AO/OTA) are severe injuries that frequently lead to bleeding and hemodynamic instability. Pelvic binders play a crucial role in their initial management. Placement at the correct level in the prehospital setting is challenging. The aim of this study was to compare two pelvic binders regarding their effectiveness in reducing intrapelvic volume and increasing intrapelvic pressure in patients with type C pelvic fractures (AO/OTA) when applied at three different levels. METHODS: Rotationally and vertically unstable pelvic injuries (AO/OTA classification 61-C1.1) were produced in five fresh-frozen human cadaveric specimens. Intrapelvic volume, vesical pressure and compression pressure within the pubic symphysis and the sacroiliac joint were measured when applying a SAM Pelvic Sling II and a T-POD at the level of the greater trochanter as well as levels higher and lower than recommended. RESULTS: Comparison of the two pelvic binders positioned at the recommended level (greater trochanter) showed no significant difference in volume reduction (13.85 ± 31.37 cm3, p = 0.442), however, increase in vesical pressure was significantly higher when using the T-POD (5.80 ± 3.27 cmH2O, p = 0.017). When positioned at the level of the iliac crest, vesical pressure increase and intrapelvic volume reduction were significantly greater with the T-POD (14.00 ± 8.57 cmH2O, p = 0.022 and 10.45 ± 5.45 cm3, p = 0.031 respectively). Application of the SAM Pelvic Sling II below the greater trochanter led to a significantly greater decrease in volume (-32.26 ± 7.52 cm3, p = 0.003) than the T-POD. Comparison of the recommended attachment level with incorrect positioning led to no significant differences for the T-POD, while the SAM Pelvic Sling II achieved a significantly lower volume reduction when placed at the iliac crest (40.15 ± 14.57 cm3, p = 0.012) and a significantly lower increase in vesical pressure when applied below the greater trochanter (3.40 ± 1.52 cmH2O, p = 0.007). CONCLUSION: Direct comparison of the two pelvic binders showed that the T-POD achieved significantly greater results when applied at the recommended level and was less susceptible to incorrect positioning. These outcomes support the preferred use of the T-POD for prehospital emergency pelvic stabilisation.

3.
Nanotheranostics ; 8(2): 163-178, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38444740

RESUMO

Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted thermometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object transfer from one system to another. Here, we present the design, development and evaluation process for integrable MFH platforms, which extends a commercial MPI scanner with the functionality of MFH. Methods: The biggest issue of integrating magnetic fluid hyperthermia platforms into a magnetic particle imaging system is the magnetic coupling of the devices, which induces high voltage in the imaging system, and is harming its components. In this paper, we use a self-compensation approach derived from heuristic algorithms to protect the magnetic particle imaging scanner. The integrable platforms are evaluated regarding electrical and magnetic characteristics, cooling capability, field strength, the magnetic coupling to a replica of the magnetic particle imaging system's main solenoid and particle heating. Results: The MFH platforms generate suitable magnetic fields for the magnetic heating of particles and are compatible with a commercial magnetic particle imaging scanner. In combination with the imaging system, selective heating with a gradient field and steerable heating positioning using the MPI focus fields are possible. Conclusion: The proposed MFH platforms serve as a therapeutic tool to unlock the MFH functionality of a commercial magnetic particle imaging scanner, enabling its use in future preclinical trials of MPI-guided, spatially selective magnetic hyperthermia therapy.


Assuntos
Hipertermia Induzida , Campos Magnéticos
4.
Arch Orthop Trauma Surg ; 144(4): 1603-1609, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38441618

RESUMO

INTRODUCTION: Distal radioulnar joint (DRUJ) instabilities are challenging and their optimal treatment is controversial. In special cases or when reconstruction of the stabilizing triangular fibrocartilage complex (TFCC) fails, K-wire transfixation can be performed. However, no consensus has been reached regarding the rotational position of the forearm in which this should be done. Therefore, it was investigated whether anatomical reduction would best be achieved by transfixation in neutral position or supination of the forearm. MATERIALS AND METHODS: Twelve cadaveric upper limbs were examined before dissection of the DRUJ stabilizing ligaments and after closed transfixation in both positions by C-arm cone-beam CT. Whether this was first done in neutral position or in supination was randomized. The change in the radioulnar ratio (RR) in percentage points (%points) was analyzed using Student's t-test. RR was used since it is a common and sensitive method to evaluate DRUJ reduction, expressing the ulnar head's position in the sigmoid notch as a length ratio. RESULTS: The analysis showed an increased change in RR in neutral position with 5.4 ± 9.7%points compared to fixation in supination with 0.2 ± 16.1%points, yet this was not statistically significant (p = 0.404). CONCLUSIONS: Neither position leads to a superior reduction in general. However, the result was slightly closer to the anatomical position in supination. Thus, transfixation of the DRUJ should be performed in the position in which reduction could best be achieved and based on these data, that tends to be in supination. Further studies are necessary to validate these findings and to identify influential factors.


Assuntos
Antebraço , Instabilidade Articular , Humanos , Supinação , Pronação , Fenômenos Biomecânicos , Articulação do Punho/cirurgia , Cadáver , Instabilidade Articular/cirurgia
5.
Foot Ankle Int ; : 10711007241231563, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38501715

RESUMO

BACKGROUND: For the temporary treatment of ankle fracture dislocations (AFDs), previous studies indicate higher rates of secondary loss of reduction (LOR) with splint immobilization, prompting consideration for expanding indications for external fixation (ExFix). However, these studies did not investigate the influence of fracture morphology to further improve patient selection. The aim of this study was to investigate the influence of Lauge-Hansen injury type on the LOR rate in bimalleolar or trimalleolar AFDs for temporary cast vs ExFix immobilization. METHODS: In this retrospective cohort study, patients with isolated AFD cases treated at our institution from 2011 to 2020 were reviewed. Inclusion criteria required radiographs depicting initial dislocation and appropriate reduction after Cast or ExFix immobilization. Exclusion criteria encompassed concomitant injuries, open fractures, conservative management as well as surgery performed within 48 hours or at a different facility. Patients were grouped by temporary treatment (Cast or ExFix). The primary endpoint was LOR prior to definitive surgery across various Lauge-Hansen types. RESULTS: The LOR rate was significantly higher in the cast group (40/152, 26.3%) compared to the ExFix group (5/191, 2.6%; P < .0001). In the cast group, LOR was associated with an increase in time to definitive surgery by a mean of 3 days (P < .002). During cast treatment, LOR was significantly more likely for pronation abduction (P = .001) and supination external rotation injuries (P < .0001), whereas no significant differences were observed for pronation external rotation (P = .006), supination adduction (P > .99), and fractures not classifiable (P > .99). CONCLUSION: In cases of AFDs resulting from supination external rotation or pronation abduction trauma according to the Lauge-Hansen classification, especially in the setting of an additional posterior malleolar fracture, primary application of external fixation should be considered to reduce the risk for secondary loss of reduction. LEVEL OF EVIDENCE: Level III, retrospective cohort study.

6.
Int J Med Robot ; 20(1): e2607, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38536717

RESUMO

BACKGROUND: The aim of the study was to validate a software-based planning method for the Schoettle Point and to evaluate precision and time efficiency of its live overlay on the intraoperative X-ray. METHODS: A software-based method was compared with surgeons' manual planning in an inter- and intrarater study. Subsequently, K-wire placement was performed with and without an overlay of the planning. The time used and the precision achieved were statistically compared. RESULTS: The average deviation between the surgeons (1.68 mm; 2.26 mm) was greater than the discrepancy between the surgeons and the software-based planning (1.30 mm; 1.38 mm). In the intrarater comparison, software-based planning provided consistent results. Live overlay showed a significantly lower positioning error (0.9 ± 0.5 mm) compared with that without overlay (3.0 ± 1.4 mm, p = 0.000; 3.1 ± 1.4 mm, p = 0.001). Live overlay did not achieve a significant time gain (p = 0.393; p = 0.678). CONCLUSION: The software-based planning and live overlay of the Schoettle Point improves surgical precision without negatively affecting time efficiency.


Assuntos
Instabilidade Articular , Luxação Patelar , Procedimentos de Cirurgia Plástica , Humanos , Luxação Patelar/diagnóstico por imagem , Luxação Patelar/cirurgia , Articulação do Joelho/cirurgia , Ligamentos Articulares , Radiografia , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia
7.
Theranostics ; 14(1): 324-340, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38164157

RESUMO

Theranostic platforms, combining diagnostic and therapeutic approaches within one system, have garnered interest in augmenting invasive surgical, chemical, and ionizing interventions. Magnetic particle imaging (MPI) offers a quite recent alternative to established radiation-based diagnostic modalities with its versatile tracer material (superparamagnetic iron oxide nanoparticles, SPION). It also offers a bimodal theranostic framework that can combine tomographic imaging with therapeutic techniques using the very same SPION. Methods: We show the interleaved combination of MPI-based imaging, therapy (highly localized magnetic fluid hyperthermia (MFH)) and therapy safety control (MPI-based thermometry) within one theranostic platform in all three spatial dimensions using a commercial MPI system and a custom-made heating insert. The heating characteristics as well as theranostic applications of the platform were demonstrated by various phantom experiments using commercial SPION. Results: We have shown the feasibility of an MPI-MFH-based theranostic platform by demonstrating high spatial control of the therapeutic target, adequate MPI-based thermometry, and successful in situ interleaved MPI-MFH application. Conclusions: MPI-MFH-based theranostic platforms serve as valuable tools that enable the synergistic integration of diagnostic and therapeutic approaches. The transition into in vivo studies will be essential to further validate their potential, and it holds promising prospects for future advancements.


Assuntos
Hipertermia Induzida , Nanopartículas de Magnetita , Termometria , Medicina de Precisão , Diagnóstico por Imagem/métodos , Nanopartículas de Magnetita/uso terapêutico , Campos Magnéticos
8.
JMIR Form Res ; 8: e47572, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38271087

RESUMO

BACKGROUND: Medical photography plays a pivotal role in modern health care, serving multiple purposes ranging from patient care to medical documentation and education. Specifically, it aids in wound management, surgical planning, and medical training. While digital cameras have traditionally been used, smartphones equipped with specialized apps present an intriguing alternative. Smartphones offer several advantages, including increased usability and efficiency and the capability to uphold medicolegal standards more effectively and consistently. OBJECTIVE: This study aims to assess whether implementing a specialized smartphone app could lead to more frequent and efficient use of medical photography. METHODS: We carried out this study as a comprehensive single-center panel investigation at a level 1 trauma center, encompassing various settings including the emergency department, operating theaters, and surgical wards, over a 6-month period from June to November 2020. Using weekly questionnaires, health care providers were asked about their experiences and preferences with using both digital cameras and smartphones equipped with a specialized medical photography app. Parameters such as the frequency of use, time taken for image upload, and general usability were assessed. RESULTS: A total of 65 questionnaires were assessed for digital camera use and 68 for smartphone use. Usage increased significantly by 5.4 (SD 1.9) times per week (95% CI 1.7-9.2; P=.005) when the smartphone was used. The time it took to upload pictures to the clinical picture and archiving system was significantly shorter for the app (mean 1.8, SD 1.2 min) than for the camera (mean 14.9, SD 24.0 h; P<.001). Smartphone usage also outperformed the digital camera in terms of technical failure (4.4% vs 9.7%; P=.04) and for the technical process of archiving (P<.001) pictures to the picture archiving and communication system (PACS) and display images (P<.001) from it. No difference was found in regard to the photographer's intent (P=.31) or reasoning (P=.94) behind the pictures. Additionally, the study highlighted that potential concerns regarding data security and patient confidentiality were also better addressed through the smartphone app, given its encryption capabilities and password protection. CONCLUSIONS: Specialized smartphone apps provide a secure, rapid, and user-friendly platform for medical photography, showing significant advantages over traditional digital cameras. This study supports the notion that these apps not only have the potential to improve patient care, particularly in the realm of wound management, but also offer substantial medicolegal and economic benefits. Future research should focus on additional aspects such as patient comfort and preference, image resolution, and the quality of photographs, as well as seek to corroborate these findings through a larger sample size.

9.
J Orthop Surg Res ; 18(1): 924, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38044441

RESUMO

BACKGROUND: Intraoperative 3D imaging using cone-beam CT (CBCT) provides improved assessment of implant position and reduction in spine surgery, is used for navigated surgical techniques, and therefore leads to improved quality of care. However, in some cases the image quality is not sufficient to correctly assess pedicle screw position and reduction, especially due to metal artifacts. The aim of this study was to investigate whether changing the acquisition trajectory of the CBCT in relation to the pedicle screw position during dorsal instrumentation of the spine can reduce metal artifacts and consequently improve image quality as well as clinical assessability on the artificial bone model. METHODS: An artificial bone model was instrumented with pedicle screws in the thoracic and lumbar spine region (Th10 to L5). Then, the acquisition trajectory of the CBCT (Cios Spin, Siemens, Germany) to the pedicle screws was systematically changed in 5° steps in angulation (- 30° to + 30°) and swivel (- 30° to + 30°). Subsequently, radiological evaluation was performed by three blinded, qualified raters on image quality using 9 questions (including anatomical structures, implant position, appearance of artifacts) with a score (1-5 points). For statistical evaluation, the image quality of the different acquisition trajectories was compared to the standard acquisition trajectory and checked for significant differences. RESULTS: The angulated acquisition trajectory increased the score for subjective image quality (p < 0.001) as well as the clinical assessability of pedicle screw position (p < 0.001) highly significant with particularly strong effects on subjective image quality in the vertebral pedicle region (d = 1.06). Swivel of the acquisition trajectory significantly improved all queried domains of subjective image quality (p < 0.001) as well as clinical assessability of pedicle screw position (p < 0.001). The data show that maximizing the angulation or swivel angle toward 30° provides the best tested subjective image quality. Angulation and swivel of the acquisition trajectory result in a clinically relevant improvement in image quality in intraoperative 3D imaging (CBCT) during dorsal instrumentation of the spine.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Tomografia Computadorizada de Feixe Cônico Espiral , Cirurgia Assistida por Computador , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada de Feixe Cônico , Imageamento Tridimensional/métodos , Cirurgia Assistida por Computador/métodos
10.
Brain Spine ; 3: 101780, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38020982

RESUMO

Introduction: There is ample evidence that higher accuracy can be achieved in thoracolumbar pedicle screw placement by using spinal navigation. Still, to date, the evidence regarding the influence of the use of navigation on the screw diameter to pedicle width ratio remains limited. Research question: The aim of this study was to investigate the implications of navigation in thoracolumbar pedicle screw placement not only on screw accuracy, but on the screw diameter to pedicle width ratio as well. Material and methods: In this single-center single-surgeon study, 45 Patients undergoing navigated thoracolumbar pedicle screw placement were prospectively included. The results were compared with a matched comparison group of patients in which screw placement was performed under fluoroscopic guidance. The screw accuracy and the screw diameter to pedicle width ratio of every screw were compared between the groups. Results: Screw accuracy was significantly higher in the navigation group compared to the fluoroscopic guidance group, alongside with a significant increase of the screw diameter to pedicle width ratio by approximately 10%. In addition, both the intraoperative radiation dose and the operating time tended to be lower in the study group. Conclusion: This study was able to show that navigated thoracolumbar pedicle screw placement not only increases the accuracy of screw placement but also facilitates the selection of the adequate screw sizes, which according to the literature has positive effects on fixation strength. Meanwhile, the use of navigation did not negatively affect the time needed for surgery or the patient's intraoperative exposure to radiation.

11.
BMC Musculoskelet Disord ; 24(1): 752, 2023 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-37742007

RESUMO

BACKGROUND: Studies have shown that pedicle screw placement using navigation can potentially reduce radiation exposure of surgical personnel compared to conventional methods. Spinal navigation is based on an interaction of a navigation software and 3D imaging. The 3D image data can be acquired using different imaging modalities such as iCT and CBCT. These imaging modalities vary regarding acquisition technique and field of view. The current literature varies greatly in study design, in form of dose registration, as well as navigation systems and imaging modalities analyzed. Therefore, the aim of this study was a standardized comparison of three navigation and imaging system combinations in an experimental setting in an artificial spine model. METHODS: In this experimental study dorsal instrumentation of the thoracolumbar spine was performed using three imaging/navigation system combinations. The system combinations applied were the iCT/Curve, cCBCT/Pulse and oCBCT/StealthStation. Referencing scans were obtained with each imaging modality and served as basis for the respective navigation system. In each group 10 artificial spine models received bilateral dorsal instrumentation from T11-S1. 2 referencing and control scans were acquired with the CBCTs, since their field of view could only depict up to five vertebrae in one scan. The field of view of the iCT enabled the depiction of T11-S1 in one scan. After instrumentation the region of interest was scanned again for evaluation of the screw position, therefore only one referencing and one control scan were obtained. Two dose meters were installed in a spine bed ventral of L1 and S1. The dose measurements in each location and in total were analyzed for each system combination. Time demand regarding screw placement was also assessed for all system combinations. RESULTS: The mean radiation dose in the iCT group measured 1,6 ± 1,1 mGy. In the cCBCT group the mean was 3,6 ± 0,3 mGy and in the oCBCT group 10,3 ± 5,7 mGy were measured. The analysis of variance (ANOVA) showed a significant (p < 0.0001) difference between the three groups. The multiple comparisions by the Kruskall-Wallis test showed no significant difference for the comparison of iCT and cCBCT (p1 = 0,13). Significant differences were found for the direct comparison of iCT and oCBCT (p2 < 0,0001), as well as cCBCT and oCBCT (p3 = 0,02). Statistical analysis showed that significantly (iCT vs. oCBCT p = 0,0434; cCBCT vs. oCBCT p = 0,0083) less time was needed for oCBCT based navigated pedicle screw placement compared to the other system combinations (iCT vs. cCBCT p = 0,871). CONCLUSION: Under standardized conditions oCBCT navigation demanded twice as much radiation as the cCBCT for the same number of scans, while the radiation exposure measured for the iCT and cCBCT for one scan was comparable. Yet, time effort was significantly less for oCBCT based navigation. However, for transferability into clinical practice additional studies should follow evaluating parameters regarding feasibility and clinical outcome under standardized conditions.


Assuntos
Parafusos Pediculares , Exposição à Radiação , Humanos , Diagnóstico por Imagem , Exposição à Radiação/prevenção & controle , Análise de Variância , Frequência Cardíaca
12.
Small ; 19(38): e2301997, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37203272

RESUMO

Magnetic particle imaging (MPI) is a powerful and rapidly growing tomographic imaging technique that allows for the non-invasive visualization of superparamagnetic nanoparticles (NPs) in living matter. Despite its potential for a wide range of applications, the intrinsic quantitative nature of MPI has not been fully exploited in biological environments. In this study, a novel NP architecture that overcomes this limitation by maintaining a virtually unchanged effective relaxation (Brownian plus Néel) even when immobilized is presented. This superparamagnetic magnetite architecture made of phenolic resin hollow spheres coated with Eu(III) containing silica nanoparticles (SMART RHESINs) was synthesized and studied. Magnetic particle spectroscopy (MPS) measurements confirm their suitability for potential MPI applications. Photobleaching studies show an unexpected photodynamic due to the fluorescence emission peak of the europium ion in combination with the phenol formaldehyde resin (PFR). Cell metabolic activity and proliferation behavior are not affected. Colocalization experiments reveal the distinct accumulation of SMART RHESINs near the Golgi apparatus. Overall, SMART RHESINs show superparamagnetic behavior and special luminescent properties without acute cytotoxicity, making them suitable for bimodal imaging probes for medical use like cancer diagnosis and treatment. SMART RHESINs have the potential to enable quantitative MPS and MPI measurements both in mobile and immobilized environments.


Assuntos
Nanopartículas de Magnetita , Nanopartículas , Óxido Ferroso-Férrico , Dióxido de Silício , Tomografia , Nanopartículas/química , Formaldeído , Fenóis , Nanopartículas Magnéticas de Óxido de Ferro , Fenômenos Magnéticos , Nanopartículas de Magnetita/química
13.
J Orthop Surg Res ; 18(1): 159, 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36864448

RESUMO

INTRODUCTION: Posttraumatic swelling causes a delay in surgery, a prolonged hospital stay and a higher risk of complications. Thus, soft tissue conditioning following complex ankle fractures is of central importance in their perioperative management. Since the clinical benefit of VIT usage on the clinical course has been shown, it should now be investigated whether it is also cost-efficient in doing so. MATERIALS AND METHODS: Included are published clinical results of the prospective, randomised, controlled, monocentric VIT study that have proven the therapeutic benefit in complex ankle fractures. Participants were allocated in a 1:1 ratio into the intervention group (VIT) and the control group (elevation). In this study, the required economic parameters of these clinical cases were collected on the data of the financial accounting and an estimation of annual cases had been performed to extrapolate the cost-efficiency of this therapy. The primary endpoint was the mean savings (in €). RESULTS: Thirty-nine cases were studied in the period from 2016 to 2018. There was no difference in the generated revenue. However, due to lower incurred costs in the intervention group, there were potential savings of about €2000 (pITT = 0.073) to 3000 (pAT = 0.008) per patient compared to the control group with therapy costs decreasing as the number of patients treated increases from €1400 in one case to below €200 per patient in 10 cases. There were 20% more revision surgeries in the control group or 50 min more OR time, respectively, and an increased attendance by staff and medical personnel of more than 7 h. CONCLUSIONS: VIT therapy has been shown to be a beneficial therapeutic modality, but it is so not only in regard to soft-tissue conditioning but also cost efficiency.


Assuntos
Fraturas do Tornozelo , Humanos , Fraturas do Tornozelo/cirurgia , Estudos Prospectivos , Pessoal de Saúde , Tempo de Internação , Tecnologia
14.
J Clin Med ; 12(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36769397

RESUMO

Studies have reported a high percentage of ankle fracture dislocations with secondary loss of reduction during primary treatment with a splint or cast. This study aimed to assess the rate of secondary loss of reduction in unimalleolar ankle fracture dislocations treated primarily with a cast or external fixator, identify the potential influence of fracture morphology, and investigate the potential implications. Unimalleolar ankle fracture dislocations with and without posterior malleolar fracture between 2011 and 2020 were included. Patients were categorized into two groups, depending on the method of temporary treatment. Fracture morphology, time to definitive surgery, and soft-tissue complications were compared. Of 102 patients, loss of reduction tended to occur more often in the cast group (17.3%) than in the external fixator group (6.0%). The presence of a posterior malleolar fracture did not have a significant influence on loss of reduction in cast immobilization; however, the fragment proved to be significantly bigger in cases with loss of reduction. No statistically significant differences in soft tissue complications or time to definitive surgery were found. Surgeons should consider the application of interval external fixation in the primary treatment of unimalleolar ankle fracture dislocations with additional posterior malleolar fractures.

15.
Chirurgie (Heidelb) ; 94(4): 292-298, 2023 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-36600030

RESUMO

Computer-assisted procedures are becoming increasingly more relevant in orthopedics and trauma surgery. The data situation on these systems has improved in recent years but still has a low level of evidence. In particular, data on short-term or medium-term results on the use of these procedures are currently available. These could show that improved precision and reproducibility of the surgical procedures can be achieved by the use of computer-assisted procedures. Nevertheless, there is still no recommendation in the current guidelines for routine use.


Assuntos
Procedimentos Ortopédicos , Robótica , Cirurgia Assistida por Computador , Robótica/métodos , Cirurgia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Computadores
16.
Sci Rep ; 13(1): 661, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36635339

RESUMO

Soft-tissue conditioning due to posttraumatic oedema after complicated joint fractures is a central therapeutic aspect both pre- and postoperatively. On average, 6-10 days pass until the patient is suitable for surgery. This study compares the decongestant effect of vascular impulse technology (VIT) with that of conventional elevation. In this monocentric RCT, 68 patients with joint fractures of the upper (n = 36) and lower (n = 32) extremity were included and randomized after consent in a 1:1 ratio. Variables were evaluated for all fractures together and additionally subdivided into upper or lower extremity for better clinical comparability. Primary endpoint was the time in days from hospital admission to operability. Secondary endpoints were total length of stay, oedema reduction, pain intensity, complications, and revisions. The time from admission until operability was reduced by 1.4 (95% CI - 0.4; 3.1) days in the mITT analysis (p = 0.120) and was statistically significant with 1.7 (95% CI 0.1; 3.3) days in the as-treated sensitivity analysis (pAT = 0.038). Significantly less pain and a faster oedema reduction were found in the intervention group. Due to rare occurrences, nothing can be concluded regarding complications and revisions. Administration of VIT therapy did not lead to a significant reduction in time until operability in the whole population but was superior to elevation for soft-tissue conditioning and pain reduction. However, there was a significant reduction by 2.5 days (95% CI 0.7; 4.3) in the subgroup of lower extremity fractures. VIT therapy therefore seems to be a helpful tool in the treatment of posttraumatic oedema after complex joint fractures of the lower and upper extremity, especially in tibial head and lower leg fractures.


Assuntos
Fraturas Ósseas , Humanos , Edema/etiologia , Fraturas Ósseas/complicações , Fraturas Ósseas/cirurgia , Articulações , Extremidade Inferior , Fatores de Tempo , Resultado do Tratamento
17.
Knee Surg Sports Traumatol Arthrosc ; 31(1): 292-298, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35994076

RESUMO

PURPOSE: Reconstruction of the medial patellofemoral ligament (MPFL-R) with nonresorbable suture tape (FiberTape®, FT) is becoming popular. Patella-side fixation of the FT can be performed with suture anchors or via soft-tissue fixation. The aim of this study was to investigate whether patella-side soft-tissue fixation can achieve equivalent primary stability compared to suture-anchor fixation. METHODS: In ten human, fresh-frozen knee joint specimens (m/f 6/4; age 74 ± 9 a), the MPFL was identified and dissected near the femoral insertion site. In five knee joints, the MPFL-R using FT was performed with soft-tissue fixation at the patella (study group; SG), and in five knee joints, the FT was fixed via suture anchors (control group, CG). All reconstructions were evaluated until load to failure of the patella-side fixation with a displacement rate of 200 mm/min. RESULTS: The mean maximum load to failure in the SG was 395.3 ± 57.9 N. All reconstructions failed by complete tearing off the medial patellar retinaculum from its medial patellar margin, but fixation of the FT remained stable. In the CG, the mean maximum load to failure was 239.4 ± 54.5 N and was significantly different compared to the SG (p = 0.04). All reconstructions failed via pullout of the suture anchors. Stiffness and elongation did not differ between the groups, and no failure of the FT was observed in any of the specimens. CONCLUSION: Primary stability of soft-tissue MPFL-R using FT was superior to suture-anchor fixation. Both fixation techniques provided sufficient primary stability, superior to previously reported native MPFL tensile strengths. MPFL-R with FT could be a possible alternative procedure for MPFL-R, eliminating potential complications due to autologous tendon graft harvesting.


Assuntos
Articulação Patelofemoral , Âncoras de Sutura , Humanos , Idoso , Idoso de 80 Anos ou mais , Articulação Patelofemoral/cirurgia , Fixação de Tecidos , Patela/cirurgia , Articulação do Joelho , Ligamentos Articulares/cirurgia , Suturas
18.
Eur J Trauma Emerg Surg ; 49(1): 373-381, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36048181

RESUMO

PURPOSE: Intraoperative 3D imaging has become a valued tool in assessing the quality of reduction and implant placement in orthopedic trauma surgery. In our institution, 3D imaging is used routinely since 2001. To evaluate the intraoperative findings and consequences of this technique, intraoperative revision rates in cases with 3D imaging were analyzed. METHODS: All operative procedures carried out with intraoperative 3D imaging between August 2001 and December 2016 were included. The scans were assessed intraoperatively and documented thereafter. In case of malreduction or misplaced implants, an immediate revision was performed. The number of scans per case as well as the findings and consequences drawn regarding the anatomical region were analyzed. RESULTS: 4721 cases with 7201 3D scans were included in this study. The most common anatomical regions were the ankle (22.3%), the calcaneus (14.8%) and the tibial head (9.5%). In 19.1% of all cases, an intraoperative revision was performed. The highest revision rates were found with 36.0% in calcaneal fractures, 24.8% in fractures of the tibial plateau, 22.3% in injuries of the ankle. In 52.0% of revisions, the reduction was improved regarding intra-articular steps or joint congruency. In 30.5% an implant was corrected. CONCLUSION: Intraoperative revision due to results of 3D imaging was performed in almost one-fifth of cases. This illustrates the improved possibilities to detect malreduction and implant misplacements intraoperatively and thus the abilities to improve surgical outcome. LEVEL OF EVIDENCE: III.


Assuntos
Fraturas Ósseas , Imageamento Tridimensional , Humanos , Imageamento Tridimensional/métodos , Fixação Interna de Fraturas/métodos , Estudos Retrospectivos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Reoperação
19.
Knee Surg Sports Traumatol Arthrosc ; 31(7): 2870-2876, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36454291

RESUMO

PURPOSE: Patellar maltracking caused by a rupture of the medial patellofemoral ligament (MPFL) can be improved by MPFL reconstruction (MPFL-R) with a tendon graft. Nonresorbable suture tape (FiberTape®, FT) is possibly becoming an option to tendon grafts for MPFL-R. Patella-side fixation of FT can be performed with suture anchors or via soft-tissue fixation. The aim of this study was to investigate patellar tracking considering soft-tissue-based and anchor-based patella-side fixation techniques. METHODS: In eight fresh-frozen human knee joint specimens (m/f 4/4; age 75 ± 10 years), the MPFL was identified, and a rupture was placed near the femoral insertion site. In the study group (SG; 4 knees), soft-tissue fixation of the FT was performed at the medial patellar retinaculum; in the control group (CG; 4 knees), FT was fixed at the patella via suture anchors. For native MPFL (nMPFL), ruptured ("injured") MPFL (iMPFL) and reconstructed MPFL (FT-MPFL-SG, respectively, FT-MPFL-CG) cone beam CT scans were performed in 15°, 30°, and 45° of knee joint flexion. Patellar tracking was assessed using the radiological parameters patellar tilt (PT), congruence angle (CA) and posterior patellar edge-trochlear groove ratio (PTR). RESULTS: All recorded radiological parameters increased, respectively, decreased in the CG and SG from the nMPFL to the iMPFL state. After MPFL-R, all parameters normalized when compared to the intact state (nMPFL), regardless of patella-side fixation technique. All investigated parameters of patellotrochlear alignment were positively, respectively, negatively significantly (p < 0.05) correlated throughout all evaluated conditions (nMPFL, iMPFL, FT-MPFL-SG, FT-MPFL-CG). CONCLUSION: MPFL-R with a nonresorbable suture tape can normalize patellar maltracking in fresh-frozen human knee joint specimens in earlier degrees of knee joint flexion independent of patella-side fixation technique. The investigated parameters of patellotrochlear alignment correlate with each other.


Assuntos
Luxação Patelar , Articulação Patelofemoral , Humanos , Idoso , Idoso de 80 Anos ou mais , Patela/cirurgia , Articulação Patelofemoral/cirurgia , Cadáver , Articulação do Joelho/cirurgia , Ligamentos Articulares/cirurgia , Suturas , Luxação Patelar/cirurgia
20.
J Orthop Surg Res ; 17(1): 474, 2022 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-36329438

RESUMO

BACKGROUND: Intraoperative cone beam CT (CBCT) imaging in dorsal instrumentation facilitates pedicle screw positioning. However, in patients with obesity, the benefit may be reduced due to artifacts that affect image quality. The purpose of this study was to evaluate whether intraoperative CBCT leads to an improved postoperative screw position compared to conventional fluoroscopy independent of body weight. METHODS: A total of 71 patients (18 patients with a BMI > 30 kg/m2, 53 patients with a BMI < 30 kg/m2) who underwent dorsal instrumentation with intraoperative CBCT imaging were included in study groups one (SG1) and two (SG2). Two control groups (CG1 and CG2) were randomly sampled to include 22 patients with a BMI > 30 kg/m2 and 60 patients with a BMI < 30 kg/m2 who underwent dorsal instrumentation without intraoperative CBCT imaging. The pedicle screw position in postoperative computed tomography was assessed using the Gertzbein-Robbins classification. RESULTS: In SG1 (BMI > 30 kg/m2), a total of 107 (83.6%) pedicle screws showed no relevant perforation (type A + B), and 21 (16.4%) pedicle screws showed relevant perforation (type C - E). In SG2 (BMI < 30 kg/m2), 328 (90.9%) screws were classified as type A + B, and 33 (9.1%) screws were classified as type C - E. In CG1 (BMI > 30 kg/m2), 102 (76.1%) pedicle screws showed no relevant perforation (type A + B), and 32 (23.9%) pedicle screws showed relevant perforation (type C - E). In CG2 (BMI < 30 kg/m2), 279 (76.9%) screws were classified as type A + B, and 84 (23.1%) screws were classified as type C - E. There were significant differences between the values of SG1 and SG2 (p = 0.03) and between the values of SG2 and CG2 (p < 0.0001). CONCLUSION: CBCT imaging in dorsal instrumentation can lead to an improved pedicle screw position among both patients with obesity and normal-weight patients. However, patients with obesity showed significantly worse pedicle screw positions postoperatively after dorsal instrumentation with intraoperative CBCT imaging than normal-weight patients.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Fusão Vertebral/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Fluoroscopia/métodos , Obesidade/complicações , Obesidade/diagnóstico por imagem , Obesidade/cirurgia , Cirurgia Assistida por Computador/métodos , Vértebras Lombares/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...